Cr(VI)DK:  Chromium (VI) Detection Kit For Water
Overview

Chromium, especially Cr(VI) due to its high carcinogenicity needs regular monitoring in drinking water due to its extensive use in various industrial process and possible release to environment. It is highly water soluble, hence labile, therefore, leads to widespread contamination from the point of source. As per Indian standard IS 10500 for drinking water, the maximum permissible contamination of Cr(VI) in drinking water is 50 µg/L. The US Environmental Protection Agency recommends a still lower permissible concentration, i.e., 10 µg/L. It is therefore essential to monitor the levels of Cr(VI) in natural water bodies.

Chromium (VI) Detection Kit is useful for quick and easy determination of Cr(VI) on field, and meets the criteria laid down by environmental agencies. Using this kit water samples can be immediately categorized as being safe, permissible or toxic for drinking from chromium (VI) point of view.

Cr(VI)DK: Chromium (VI) Detection Kit For Water
Quick View Leaflet

Ensuring safe drinking water for human beings worldwide is a top priority for all agencies concerned because its quality causes direct impact on human health. Chromium is widely used in various industries like steel, chromo plating, paint manufacturing, leather treatment, wood preservation and as corrosion inhibitor. It exists in the environment primarily in two valence states, trivalent chromium, Cr(III) and hexavalent chromium, Cr(IV). Cr(III) is biologically important element and is needed for glucose and lipid metabolism. Cr (VI) however is considered toxic and IARC (International Agency for Research in Cancer, WHO) has classified it as a group 1 agent, defined as carcinogenic to humans. As per Indian Standard IS10500 for drinking water, the maximum permissible concentration of Cr(VI) in drinking water is 50 µg/L. The US Environmental Protection Agency recommends a still lower permissible concentration, i.e. 10 µg/L. For detection at such low levels, very sophisticated instrumentation such as HPCL-ICPMS is necessary, which are not suitable for field work. Onsite estimation of Cr(VI) is possible only by a field method which is sensitive enough to detect Cr(VI) at 10 µg L-1. Current methods practiced for field applications are not sensitive to this level.

BARC has developed a quick, easy and affordable kit for onsite determination of Cr(VI), which meets IS10500 as well as EPA criteria. Cr(VI) DK is a simple, user-friendly and highly cost effective kit for estimation of chromium (VI) in drinking, tap, lake, river and ground water in comparison to the currently available techniques. The procedure is as simple as adding a specified amount of reagents to the water sample and identifying the color developed. The color develops with in 5 minutes and the distinction can be made with the naked eye. For ease of comparison a color chart is provided with the kit. Water samples can be immediately categorized as being safe or toxic for drinking from chromium (VI) point of view.

ADVANTAGES

  • Onsite detection & Instantaneous results

  • Eliminates the use of sophisticated instruments for analysis

  • Low investment on infrastructure for producing the kits

  • Easy availability of the raw-materials

  • Good accuracy for the intended purpose
Cr(VI)DK: Chromium (VI) Detection Kit For Water
Detail Technical Brochure

Chromium is widely used in various industries like steel, chromo plating, paint manufacturing, leather treatment, wood preservation and as corrosion inhibitor. It exists in the environment primarily in two valence states, trivalent chromium, Cr(III) and hexavalent chromium, Cr(IV). Cr(III) is biologically important element and is needed for glucose and lipid metabolism. Cr (VI) however is considered toxic and IARC (International Agency for Research in Cancer, WHO) has classified it as a group 1 agent, defined as carcinogenic to humans. As per Indian Standard IS10500 for drinking water, the maximum permissible concentration of Cr(VI) in drinking water is 50 µg/L. The US Environmental Protection Agency recommends a still lower permissible concentration, i.e. 10 µg/L. For detection at such low levels, very sophisticated instrumentation such as HPCL-ICPMS is necessary, which are not suitable for field work. Onsite estimation of Cr(VI) is possible only by a field method which is sensitive enough to detect Cr(VI) at 10 µg L-1. Current methods practiced for field applications are not sensitive to this level.

BARC has developed a quick, easy and affordable kit for onsite determination of Cr(VI), which meets IS10500 as well as EPA criteria. Cr(VI) DK is a simple, user-friendly and highly cost effective kit for estimation of chromium (VI) in drinking, tap, lake, river and ground water in comparison to the currently available techniques. The procedure is as simple as adding a specified amount of reagents to the water sample and identifying the color developed. The color develops with in 5 minutes and the distinction can be made with the naked eye. For ease of comparison a color chart is provided with the kit. Water samples can be immediately categorized as being safe or toxic for drinking from chromium (VI) point of view.

ADVANTAGES

  • Onsite detection & Instantaneous results
  • Eliminates the use of sophisticated instruments for analysis
  • Low investment on infrastructure for producing the kits
  • Easy availability of the raw-materials
  • Good accuracy for the intended purpose

DESCRIPTION

The Cr(VI)DK kit consists of

a) Cr(VI) DK reagents : 3 bottles (250 mL)
b) Mixing reagent : 1 bottle (250 mL)
c) Tablet box : 1 box (250 tablets)
d) Graduated 15 mL polypropylene test-tubes : 5 Nos.
e) Color Chart : 1 No.

REQUIREMENTS

A. Infrastructure Requirements

  • A laboratory room (3m X 3m) with the following equipment:
    2 glass beakers (250 mL), 1 measuring jar (1L), balance (1 mg precision), pelletizer (10 mm dia), and powder pulveriser.

B. Statutory Requirements

  • Statutory clearances for safe handling of various acids, chemicals and a small scale industrial registration is required.

C. Raw materials

  • All the raw materials required to utilize the technology for making the chromium (VI) detection kits are freely available in the Indian market.

D. Manpower requirements

  • One technician for preparing the reagents and pellets, one chemist for carrying out the reagent quality assessment by checking with standards.

List of Active Licensee for “Cr(VI)DK: Chromium(VI) Detection Kit for water” technology

SN Party Details
1 Dr. C. L. Lakhotia, partner,
M/s LTEK Systems,

2-B, Rajkamal Complex, Panchsheel Square,
Wardha Road, Dhantoli,
Nagpur- 440012
Phone: +91-9420251777 (M) / 0712-2442230 / 2726160
E-mail: vishva_ngp@yahoo.com

Who Should apply


Interested parties with Engineering & Scientific knowledge, good financial background and adequate experience of products manufacturing & fabrication with technical capability in the area of interested technology and having or interested in setting –up facilities for production would be preferred.


How to apply

Send your Technology Transfer Application form duly filled and signed alongwith a Demand Draft/Bankers cheque of Rs. 500/- (for Indian entities) or US $50/- (for foreign entities) drawn in favour of “Accounts Officer, BARC” as application processing fee on following address: 

Head, Technology Transfer and Collaboration Division 
Bhabha Atomic Research Centre,
Trombay, Mumbai – 400 085, India.

Fax : +91-22-25505151


Note:Applications without processing fee as applicable above of Rs. 500/- or US $50/- for each technology will not be considered.


Click here for Technology Transfer Application Form

Contact Us

Head, 
Technology Transfer and Collaboration Division
Bhabha Atomic Research Centre,
Trombay, Mumbai 400 085.

Fax : 091-022- 25505151
Email : technology@barc.gov.in

How to apply

BACK
 
Top Close